Quantitative results for the direct participation of the parenchymal vascular system in cerebral waste removal

Published: 23 November 2022
Abstract Views: 214
PDF: 134
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

Background: Impaired cerebral waste clearance (CWC) has been associated with a broad range of both physiological and pathophysiological neurologic conditions.1,2 Because of the unique anatomy of the brain parenchyma, theoretically, in the brain parenchyma, biochemically inert waste such as magnetic resonance imaging (MRI) contrast agents can only be removed through two possible pathways: cerebrospinal fluid (CSF) pathway, and/or vascular pathway. Despite the controversy, there seems to be a solid consensus on the participation of the CSF pathway in CWC.3 In contrast to the CSF system, the current consensus is that the parenchymal vascular system does not participate in CWC. Considering there is a big difference in flow rate between the blood (2 mL/min) and the CSF (3.7 µL/min) and the brain is the most bioactive, energy-consuming organ (20% nutrition for about 5% of body weight) in the body, it is illogical that the brain would rely on the slow CSF circulation for CWC while less bioactive tissues outside the brain require both the fast vascular and slow lymphatic systems to remove waste in a timely manner.4,5

Methods: Superparamagnetic iron oxide–enhanced susceptibility-weighted imaging (SPIO-SWI) and quantitative susceptibility mapping (QSM) methods were used to simultaneously study 7 T MRI signal changes in parenchymal veins, arteries, and their corresponding para-vascular spaces in 26 rats, following intra-cisterna magna (ICM) infusion of different CSF tracers (FeREX, ferumoxytol, Fe-Dextran) to determine the amount of tracer in the artery and vein quantitatively.

Results: The parenchymal venous system participated in CSF tracer clearance following ICM infusion of different MRI tracers with different concentrations of iron. Parenchymal venous participation was more obvious when 75 μg iron was injected. In the parenchymal veins, the relative mean (±SE) value of the susceptibility increased by 13.5±1.0% at 15 min post-tracer infusion (p<0.01), and 33.6±6.7% at 45 min post-tracer infusion (p=0.01), compared to baseline. In contrast to the parenchymal veins, a negligible amount of CSF tracer entered the parenchymal arteries: 1.3±2.6% at 15 min post-tracer infusion (p=0.6), and 12±19% at 45 min post-tracer infusion (p=0.5), compared to baseline.

Conclusions: MRI tracers can enter the parenchymal vascular system and more MRI tracers were observed in the cerebral venous than arterial vessels, suggesting the direct participation of parenchymal vascular system in CWC.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

1. Iliff JJ, Wang M, Liao Y et al. A paravascular pathway facilitates CSF flow through the brain parenchyma and the clearance of interstitial solutes, including amyloid beta. Sci Transl Med 2012;4:147ra111.
2. Xie L, Kang H, Xu Q et al. Sleep drives metabolite clearance from the adult brain. Science 2013;342:373-377.
3. Jessen NA, Munk AS, Lundgaard I, Nedergaard M. The Glymphatic System: A Beginner's Guide. Neurochem Res 2015;40:2583-2599.
4. Brinker T, Stopa E, Morrison J, Klinge P.A new look at cerebrospinal fluid circulation. Fluids Barriers CNS 2014;11:10.
5. Iliff JJ, Wang M, Zeppenfeld DM et al. Cerebral arterial pulsation drives paravascular CSF-interstitial fluid exchange in the murine brain. J Neurosci 2013;33:18190-18199.

How to Cite

Hu, J., Shen, Y., Fahmy, L. M., Krishnamurthy, S., Li, J., Zhang, L., Chen, Y., Haacke, M. E., & Jiang, Q. (2022). Quantitative results for the direct participation of the parenchymal vascular system in cerebral waste removal. Veins and Lymphatics, 11(1). https://doi.org/10.4081/vl.2022.10950