Venous leakage treatment revisited: pelvic venoablation using aethoxysclerol under air block technique and Valsalva maneuver


Submitted: April 1, 2015
Accepted: April 1, 2015
Published: March 31, 2015
Abstract Views: 4417
PDF: 3774
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

Objective: We evaluated the effectiveness of pelvic vein embolization with aethoxysclerol in aero-block technique for the treatment of impotence due to venous leakage in men using sildenafil for intercourse. The aim of the procedure was to reduce the use of sildenafil. Methods: A total of 96 patients with veno-occlusive dysfunction, severe enough for the need of PDE5 inhibitors for vaginal penetration, underwent pelvic venoablation with aethoxysclerol. The mean patient age was 53.5 years. Venous leaks were identified by Color Doppler Ultrasound after intracavernous alprostadil injection. Under local anesthesia a 20-gauge needle was inserted into the deep dorsal penile vein. The pelvic venogram was obtained through deep dorsal venography. Aethoxysclerol 3% as sclerosing agent was injected after air-block under Valsalva manoeuver. Success was defined as the ability to achieve vaginal insertion without the aid of any drugs, vasoactive injections, penile prosthesis, or vacuum device. Additionally, a pre- and post- therapy IIEF score and a digital overnight spontaneous erections protocol (OSEP) with the NEVA™-system was performed. Results: At 3 month follow-up 77 out of 96 patients (80.21%) reported to have erections sufficient for vaginal insertion without the use of any drug or additional device. Four (4.17%) patients did not report any improvement. Follow up with color Doppler ultrasound revealed a new or persistent venous leakage in 8 (8.33%) of the patients. No serious complications occurred. Conclusions: Our new pelvic venoablation technique using aethoxysclerol in air-block technique was effective, minimally invasive, and cost-effective. All patients were able to perform sexual intercourse without the previously used dosage of PDE5 inhibitor. This new method may help in patients with contra-indications against PDE5 inhibitors, in patients who cannot afford the frequent usage of expensive oral medication or those who do not fully respond to PDE5-inhibitors.

Herwig, R., & Sansalone, S. (2015). Venous leakage treatment revisited: pelvic venoablation using aethoxysclerol under air block technique and Valsalva maneuver. Archivio Italiano Di Urologia E Andrologia, 87(1), 1–4. https://doi.org/10.4081/aiua.2015.1.1

Downloads

Download data is not yet available.

Citations