Comparison of the urethrovesical anastomoses with polyglecaprone (Monocryl®) and bidirectional barbed (V-Loc 180®) running sutures in laparoscopic radical prostatectomy

Submitted: July 9, 2014
Accepted: July 9, 2014
Published: June 30, 2014
Abstract Views: 2749
PDF: 1687
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

Objective: We compared polyglecaprone (Monocryl®) and bidirectional barbed (V-Loc® 180) running sutures during urethrovesial anastomosis (UVA) in laparoscopic radical prostatectomy (LRP). Materials and methods: A total of 92 consecutive patients underwent extraperitoneal LRP for prostate cancer. In the first 47 patients, the running UVA was performed using 3-0 monofilament polyglecaprone (Monocryl®) suture (Group 1). In the subsequent 45 patients, the running UVA was performed with the 3-0 barbed suture (V-Loc® 180) (Group 2). Rhabdosphincter reconstruction was performed in all the patients. Results: The mean prostatectomy time was 196 and 179 minutes in Group 1 and 2, respectively (p < 0.001). Moreover, the mean UVA time was 40 and 24 minutes in Group 1 and 2, respectively (p < 0.001). Also, catheterization time, lenght of hospital stay and the number of the patients with urine leakage were significantly lower in Group 2 than the other (p < 0.001). No patients in V-Loc® 180 suture group and 5 patients in Monocryl® suture group experienced postoperative drain leakage in the present study. Overall pad usage at 6th month was higher in group 1 than the other group. In group 1 and 2, 78.7% and 93.3% of the patients reported 0 to 1 pads daily, whereas 21.3% and 6.7% reported ≥ 2 pads daily (p = 0.002). Conclusions: We therefore consider that use of barbed suture running UVA during LRP is associated with a significantly shorter operative time maintaining a proper suturing tension compared with standard suture and it is not associated with a higher incidence of adverse events with no postoperative complications.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Citations

How to Cite

Arslan, M., Tuncel, A., Aslan, Y., Kozacioglu, Z., Gunlusoy, B., & Atan, A. (2014). Comparison of the urethrovesical anastomoses with polyglecaprone (Monocryl®) and bidirectional barbed (V-Loc 180®) running sutures in laparoscopic radical prostatectomy. Archivio Italiano Di Urologia E Andrologia, 86(2), 90–94. https://doi.org/10.4081/aiua.2014.2.90